2869 entries curated across talks and posters.
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of New CBCT Image Reconstruction Algorithms for Proton Adaptive Therapy Workflows
To evaluate the imaging performance, Hounsfield Unit (HU) accuracy, and proton‑dose calculation implications of three newly released Varian ProBeam 360⁰ CBCT reconstruction algorithms—iCBCT, iCBCT Acuros, and iCBCT MAR Adaptive—c...
Eunsin Lee, PhD
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of Patient-Specific Autosegmentation Via Intentional Overfitting: Assessing Lightweight Architectures for Accelerated Online Workflow In Mrgart for Prostate Cancer
Deep learning-based organ contouring is essential for optimizing the MR-guided adaptive radiotherapy (MRgART) workflow. However, online contouring remains challenging because of interfractional anatomical variations. This study d...
Toshitaka Takahashi
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of Planning Target Margins In Head and Neck Cancer Radiotherapy: A Multicentric Experience from Bangladesh
Head and neck cancers (HNC) pose unique challenges due to anatomical complexity and setup uncertainties during radiotherapy. In resource-limited settings like Bangladesh, standardized planning target volume (PTV) margins may inad...
Md. Jobairul Islam, M.Sc
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of Plastic Scintillation Detectors for Quality Assurance In Non-Coplanar Stereotactic Radiotherapy
Non-coplanar arc irradiation is widely used in stereotactic radiotherapy to achieve highly conformal dose distributions for small targets. For patient-specific quality assurance (PSQA), detector performance must remain stable und...
Shuichi Ozawa, PhD
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of Plastic Scintillator Detector for In-Vivo Dosimetry
To develop and characterize plastic scintillator sheets for in-vivo dosimetry to measure entrance dose distributions for therapeutic photon, electron, and proton beams.
Nesreen Alsbou, PhD
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of Radiation Dose to Thoracic Organs from 3D Versus 4D CBCT Using Radiophotoluminescent Glass Dosimeters
Four-dimensional cone-beam computed tomography (4D-CBCT) provides respiratory motion–resolved imaging for image-guided radiotherapy (IGRT) in thoracic treatments but may increase imaging dose compared with conventional three-dime...
Sakda Kingkaew
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of Radiomic Feature Repeatability from a Novel CBCT System
The novel Varian TrueBeam HyperSight-CBCT (HS-CBCT) aims to overcome image non-uniformity and artifacts in conventional CBCT. While radiomic feature repeatability has been investigated for conventional CBCT, the performance of HS...
Takato Kamishima
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of Rapidplan Model Performance after an Eclipse Version Upgrade
RapidPlan, a knowledge-based treatment planning tool integrated in Varian’s Eclipse treatment planning system, has been shown to improve radiotherapy planning efficiency and consistency. The aim of this study is to evaluate the p...
Wei Zhao, PhD
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of Relationship between Non-Adaptive Composite Dose and Adaptive Fraction Utilization
Online adaptive stereotactic body radiation therapy (SBRT) enables daily replanning to mitigate anatomic variation but increases treatment time and clinical workload. For left adrenal tumors, adaptive SBRT is frequently assigned...
Emily Sigmund
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of Respiratory Motion Effects In VMAT Lattice Spatially Fractionated Radiotherapy Using 4DCT
To evaluate the impact of respiratory motion on dose distribution and spatial modulation in VMAT-based Lattice Spatially Fractionated Radiotherapy(Lattice-SFRT), and to evaluate the stability of peak–valley dose characteristics u...
Mingyuan Ye
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of Single- Versus Multi-Point Barometer Calibration for Reference Dosimetry
AAPM WGTG51 Report 374 emphasizes the importance of field barometer cross-calibration versus a reference barometer prior to reference dosimetry measurements. This work evaluates the validity of single-point calibration across alt...
Jainam Hiteshkumar Valand
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of Spot-Wise Monitor Unit Delivery Errors In Spot-Scanning Proton Arc Therapy
To evaluate the robustness of spot-scanning proton arc therapy (SPArc) to stochastic spot-wise monitor unit (MU) delivery errors.
Peilin Liu
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of Surface-Guided Breath-Hold for Motion Control In CBCT-Guided Online Adaptive Radiotherapy
CBCT-based online adaptive radiotherapy (CBCT-oART) enables daily plan adaptation but is sensitive to intra-fraction motion during extended adaptive workflows. This study evaluates breath-hold (BH) motion stability and workflow i...
Xinran Zhong
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of the Biological Effectiveness of Mixed Sphere Size Spatially Fractionated Radiation Therapy Using Gamma-Knife Vs. VMAT
To evaluate the biological effect of Spatially Fractionated Radiation Therapy (SFRT) using Gamma Knife (GK) or volumetric-modulated arc therapy (VMAT) with multiple sphere sizes in a lattice arrangement.
Casey E McGrath
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of the IDENTIFYTM Optical Surface Guidance System for Craniospinal Irradiation Patient Positioning
Craniospinal irradiation (CSI) can be delivered using a multi-isocentre technique. This requires a time-consuming alignment process using kV orthogonal imaging followed by cone-beam CT (CBCT) to ensure alignment accuracy across m...
Ranslee MacLennan, BSc
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of the Iterative Model Reconstruction (IMR) Algorithm for Four-Dimensional Computed Tomography (4DCT)
This work investigates use of the IMR algorithm in 4DCT for potential dose reduction in patients.
Benjamin D. Schultz
Diagnostic and Interventional Radiology Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of the Reproducibility of a Modified Aapm TG-126 Spatial Resolution and PET/CT Registration Test
To evaluate the reproducibility of a PET/CT QA test for assessing spatial resolution and image registration.
Nathaniel Davis Teague
Radiopharmaceuticals, Theranostics, and Nuclear Medicine
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of the Sun Nuclear Sunsilicon Diode for Small-Field Dosimetry In 1.5 T and 0.35 T MR-Linacs
Accurate small‑field dosimetry on MR‑linacs remains challenging due to magnetic‑field–induced dose perturbations and steep dose gradients. In this study, the performance of a newly developed unshielded silicon diode has been eval...
Caiden Kohl Atienza
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of Varian RapidPlanPT DVH Estimates Against Clinically Delivered Plans for Head and Neck Cancer Treated with Proton Radiation Therapy
To evaluate the agreement between Varian RapidPlanPT DVH estimates and clinically delivered plans using an independent validation set for head and neck cancer (HNC) treated with proton radiation therapy.
Brandon Reber, PhD
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Evaluation of VMAT Patient Specific Quality Assurance Using Suncheck on the Halcyon Linear Accelerator
To evaluate the dosimetric accuracy of SunCHECK, a calculation-based IMRT patient specific quality assurance (PSQA) program, when applied to VMAT PSQA for the Halcyon LINAC.
Ju-Young Song, PhD
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Expanding the Range of Extracted Dynamic FET Features As Candidate Glioblastoma Response Biomarkers
To assess the feasibility of using radiomics features from dynamic FET imaging parameterizations as potential biomarkers of glioblastoma (GBM) treatment response by evaluating the repeatability of parametric-map radiomic features...
Martin Andrew Ebert, PhD
Radiopharmaceuticals, Theranostics, and Nuclear Medicine
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Experimental and Simulated H2O2 Radiolytic Yields In Ultra-Pure Water Under Proton Irradiation at High Dose Rate.
High-dose-rate (HDR, >40 Gy/s) irradiation can enhance the tolerance of healthy tissue. To investigate water radiolysis in proton irradiations (IBA Cyclone 70 XP, Nantes, France) for dose rates ranging from 0.2 Gy/s to 115 Gy/s,...
Daeun Kwon
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Experimental Benchmarking and Validation of a Clinical Photon-Counting CT Simulation
To develop and validate the first open-source, CdTe-based photon-counting CT (PCCT) simulation framework using CATsim. The goal was to emulate clinical PCCT performance and quantitatively compare simulated versus experimental iod...
Andrew J Skivington
Diagnostic and Interventional Radiology Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Experimental Evaluation of Proton Therapy Transmission Spots Using Hybrid Gamma Imaging
Proton therapy shielding design typically assumes that protons stop within the patient. However, modern treatment planning optimization strategies may introduce high-energy proton transmission (“shoot-through”) spots that exit th...
Chester R. Ramsey, PhD
Therapy Physics
0 people interested