Institution profile

University Medical Center Utrecht

Rank #96 · 10 unique linked submissions.

People

Top contributors

Poster Poster Program
Assessing the Octavius 4D MR Phantom for VMAT Validation on the 1.5 T MR-Linac

MR-linacs enable online adaptive radiotherapy, which increases dose conformality and thus potentially improves therapeutic ratios. A recurring drawback with respect to C-arm linacs is the lack of VMAT leading to decreased efficiency. Recently, it was demonstr...

Bas W. Raaymakers, PhDPim T. S. Borman, PhDCarmen HoekMartin F. Fast, PhD
Therapy Physics
Poster Poster Program
Impact of Fluence-Based Constraints on VMAT Plan Optimization

Volumetric-modulated arc therapy (VMAT) plan optimization remains a challenging problem due to its non-convex character and the large dimensionality of the solution space. Commonly, the problem is split in three steps: 1) ideal fluence optimization 2) arc seq...

Cornel Zachiu, PhDParis TzitzimpasisGijs H. Bol, PhDBas W. Raaymakers, PhDMartin F. Fast, PhD
Therapy Physics
Poster Poster Program
Can VMAT Reduce Treatment Time on the MR-Linac without Compromising Plan Quality?

This study investigates the feasibility of VMAT treatments on the MR-Linac by comparing planned and measured quality and deliverability of investigational VMAT plans with existing clinical IMRT plans to determine whether VMAT can maintain clinically acceptabl...

Carmen HoekPim T. S. Borman, PhDGijs H. Bol, PhDLouk M.W. SnoerenBas W. Raaymakers, PhDMartin F. Fast, PhD
Therapy Physics
Poster Poster Program
Consistent Multi-Modal Ventilation Imaging for Online Adaptive Radiotherapy Using Biomechanically Constrained Deformable Image Registration

Computed tomography ventilation imaging (CTVI) allows generating ventilation maps from CT data. CTVI provides spatially resolved information on regional lung function that can support functional avoidance and adaptive treatment strategies, but its current rel...

Charlotte JansenMario Ries, PhDCornel Zachiu, PhDBas W. Raaymakers, PhDParis TzitzimpasisKatrinus Keijnemans, PhD
Therapy Physics
Poster Poster Program
Development and Initial Characterization of an MRI-Compatible Multi-Point Dosimetry Array

Dosimetric quality assurance (QA) is essential for treatment validation on the MR-linac. However, many conventional QA approaches are challenging in the presence of a magnetic field. In this study a plastic scintillator multi-point QA dosimeter array designed...

Laurie J. M. de VriesPim T. S. Borman, PhDSimon J. Woodings, PhDMartin F. Fast, PhD
Therapy Physics
Poster Poster Program
Reducing IMRT Delivery Times By Accelerating Segment Loading and MLC Positioning for the 1.5 T MR-linac

Intensity modulated radiotherapy (IMRT) is the current standard delivery technique on MR-linacs. IMRT deliveries cycle between radiating and moving segments, each starting with loading the segment. More complex plans usually contain more radiating segments, i...

Bas W. Raaymakers, PhDThomas A. FoppenMartin F. Fast, PhDPim T. S. Borman, PhDCarmen HoekKatrinus Keijnemans, PhD
Therapy Physics
Paper Proffered Program
Fast Daily Auto-Contouring for Adaptive Cervical Cancer Treatments on the MR-Linac.

Effectiveness of EBRT depends highly on target coverage, which is challenged by inter- and intra-fraction anatomical motion. MR-guided radiotherapy (MRgRT) reduces the need for inter-fraction planning margins, by daily adaptive planning, for which daily recon...

Astrid L.H.M.W. van Lier, PhDSaskia L.C. Damen, MSc.Bas W. Raaymakers, PhDDorine S.J. Tseng, M.D.Cornel Zachiu, PhD
Therapy Physics