To develop cross-attention-based multi-modal deep learning models and to preliminarily validate their performance for predicting local recurrence (LR) in patients with non-small cell lung cancer (NSCLC).
Library
All conference submissions
2869 entries curated across talks and posters.
To investigate the value of CT-based radiomics for preoperative prediction lymph node status of the esophagogastric junction adenocarcinoma.
We aim to compare cervical cancer brachytherapy treatment plans created using custom 3D-printed patient-specific cylindrical templates (PSCTs) to commercially available hybrid interstitial applicators (Geneva/Venezia, Elekta).
Standard image-guided radiotherapy(IGRT) approaches for muscle invasive bladder cancer(MIBC) require large target margins due to bladder fill variability, inevitably resulting in increased organ-at-risk(OAR) doses and toxicity ri...
Hybrid tangential breast radiotherapy commonly uses a high proportion of open fields to enhance robustness against inter-fraction anatomical variation, potentially limiting planning flexibility. In five-fraction hypofractionated...
Brachytherapy is a standard component in cervical cancer treatment. Venezia applicators allow addition of limited needle positions to tandem and ovoid procedures, but needle selection and insertion depth largely rely on physician...
Magnetic resonance-guided set up images (MRg-images) acquired prior to daily treatment provide longitudinal image series that could contain treatment response information. The purpose of this work is to compare delta radiomics te...
Cherenkov Imaging is the method by which the light emitted from a patient’s skin during external beam radiation therapy can be imaged and used to verify dose delivery location. This is accomplished using an intensified CMOS camer...
Validation of online plan adaptation is complex, especially in the context of a MR-Linac where there are very few commercial phantoms available. The purpose of this study is to design and manufacture a modular, simple and low-cos...
To enhance image quality for image-guided radiotherapy (IGRT) by determining the most optimal combination of filter and noise suppression level used in iterative reconstruction of cone beam CT data (iCBCT) acquired with a new ima...
Diffusing alpha-emitters Radiation Therapy (Alpha DaRT) requires accurate placement of radioactive sources to ensure full coverage of the Gross Tumor Volume (GTV) while minimizing the required total number and length of implanted...
The purpose of this study was to characterize carbon-ion radiation transport and energy deposition for the Brookhaven National Laboratory (BNL) experimental platform using deterministic TRiP98 (GSI heavy-ion treatment planning sy...
An educational endeavor has been initiated to provide the diagnostic radiology (DR) community with an up-to-date resource describing the physics and clinical implementation of DR imaging physics. The resource will be widely, and...
To develop a simple protocol for dose verification of Leipzig surface HDR applicators using Gafchromic EBT3 film.
To establish standardized, probe-specific depth of penetration baselines for protocol-specific clinical use across ultrasound transducers to support routine quality assurance (QA), enable early detection of probe degradation, and...
Cervical cancer remains a major global health burden, with Image-guided High-Dose-Rate Brachytherapy (HDR-BT) serving as a critical treatment modality. While MRI is the gold standard for defining the Gross Tumor Volume (GTV), Hig...
Development of a deep learning model for accurate preoperative identification of glioblastoma and solitary brain metastases by combining multi-centre and multi-sequence magnetic resonance images and comparison of the performance...
Accurate and efficient dose calculation remains a major challenge in boron neutron capture therapy (BNCT) due to the complexity of neutron transport and the contribution of secondary particles. Conventional Monte Carlo (MC) metho...
Anatomic motion and deformation modeling using digital twins (DTs) hold much promise for radiotherapy applications. However, clinical implementation is limited by availability of high-quality data, computationally intensive and u...
Continuous glucose monitoring (CGM) provides high-resolution time-series data reflecting real-world glucose dynamics. However, most existing CGM analytics emphasize absolute glucose values, numerical thresholds, or food-centric i...
Stereotactic radiosurgery (SRS) delivered with linear accelerators requires submillimetric mechanical, geometric, and dosimetric accuracy. Although postal and remote audit programs are widely available, they do not fully capture...
The goal of this study is to develop a simple treatment planning system (TPS) to assess the dosimetry of a Y-90 source train-based treatment for intravascular brachytherapy (IVBT) using data from Monte-Carlo simulations.
To develop and evaluate a clinically practical single-isocenter stereotactic radiosurgery (SRS) planning strategy for patients with multiple brain metastases in RayStation, with the goals of establishing institutional planning gu...
To develop a Web-Based Theranostic Workflow Management Tool (TWMT) to efficiently manage Theranostic program in the department of radiation oncology (RadOnc).