Histology-Based Microscale Human Spleen Model for Radiopharmaceutical Therapy Dosimetry
For radiopharmaceuticals emitting high linear energy transfer (LET) particles, such as alpha particles, the spleen can receive substantial localized doses due to its reticuloendothelial function. To capture dose heterogeneity, th...
Spencer Frederick Salminen
Radiopharmaceuticals, Theranostics, and Nuclear Medicine
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Hybrid Framework Combining Pre-Trained Supervised Image Priors with Neural Representation for Extremely Sparse-View CT Reconstruction (HYPER)
Extremely sparse-view CT benefits for reducing radiation dose while causing streak artifact when using the traditional filtered-back projection (FBP). We propose a new learning-based reconstruction method, named HYPER (HYbrid fra...
Geumbong Ji
Diagnostic and Interventional Radiology Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Hybrid Respiratory Motion Tracking Using X-Ray Imaging and Integrated Infrared Cameras In a Mobile Cone-Beam CT System
To assess the agreement in motion tracking at a mobile cone-beam computed tomography (CBCT) X-ray imaging system integrating optical cameras, at varying gantry angle and controlled breathing periods.
Prasannakumar Palaniappan, PhD
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Hydrated-Electron Dosimetry for Proton Flash Beams: Feasibility and Response Characterization
To evaluate the feasibility of a hydrated-electron dosimeter prototype for proton FLASH beams and to characterize its sensitivity and response.
Jingyi Bian
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Hypersight-Archer Head and Neck Clinical Trial: Image Quality and Dose Calculation Accuracy In the Presence of Metal Artifacts
This work evaluates Varian’s HyperSight CBCT system installed on the Ethos radiotherapy platform using head-and-neck (H&N) patient cases to characterize the image quality and dose-calculation accuracy in the presence of metal-ind...
Abby Yashayaeva, MSc
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Hypersight CBCT–Based Simulation on Ethos: Workflow Development and Dosimetric Assessment
To evaluate the feasibility of HyperSight CBCT–based radiotherapy planning on the Varian Ethos v2.0 platform and to develop a clinically deployable simulation workflow that overcomes current system limitations.
Sarah Rosemary Morris, PhD
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Hypersight CBCT on Conventional Linac for Adaptive Prostate Radiotherapy: Evaluating Image Quality, HU Stability, and Metal Artifact Reduction
Kilovoltage cone-beam CT (kV-CBCT) is routinely used for image-guided radiotherapy (IGRT). However, image artifacts and limited Hounsfield unit (HU) stability strict its application in adaptive radiotherapy. Recently, HyperSight...
Lan Lu
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Hypersight CBCT Preserves CT-like Radiomic Biomarkers Better Than Conventional CBCT In Pelvic Radiotherapy
Radiomics-enabled adaptive radiotherapy depends on on-treatment imaging that maintains CT-like quantitative biomarkers. We evaluated whether HyperSight CBCT preserves planning-CT radiomic biomarkers more faithfully than conventio...
Yushi Chang, PhD
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Hypersight Slow-Scan CBCT Supports Reliable Target Delineation and Dosimetric Improvement In Online Lung Adaptive Radiotherapy
Online adaptive lung radiotherapy has not been widely reported due to challenges in respiratory motion. This study evaluates the clinical performance of HyperSight slow-scan CBCT for target delineation, dose calculation accuracy,...
Yi-Fang Wang, PhD
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Identifiability, Effective Dimensionality, and Interpretability In PBPK-Based Alpha Rpt Dosimetry
Quantitative image-based dosimetry for radiopharmaceutical therapy (RPT) increasingly relies on large, multi-organ mechanistic models of physiologically based pharmacokinetics (PBPK). While PBPK models often fit clinical data wel...
Mark K Transtrum, PhD
Radiopharmaceuticals, Theranostics, and Nuclear Medicine
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Identification of Dwell-Times with In-Vivo Scintillation Detectors In Brachytherapy
Plastic Scintillation Detectors (PSD) have shown great potential for dose measurements, but extraction of dwell-time in particular sub-seconds is plagued with small signal. This study aims to evaluate inorganic scintillator (ISD)...
Audrey-Anne Piché
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Image-Guided Radiation Therapy Practices In Low- and Middle-Income Countries: A Multi-Institutional Survey and Initial Findings
To evaluate the use of image-guided radiation therapy (IGRT) tools and physics plan review practice in low- and middle-income countries (LMICs). By identifying barriers to IGRT implementation, this study aims to inform best pract...
Hana Baroudi, PhD
Professional
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Image Quality Characterization of on-Board Kilovoltage-CBCT Systems on Modern Linear Accelerator Units
To quantitatively evaluate and compare imaging performance of various kV-CBCT systems implemented on modern C-arm and O-ring linear accelerator units.
Riley C. Tegtmeier, MS
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Image Quality Comparison of Post-Processed True Axial Head CT Reconstructions with Direct Reconstructions on Scanner
To investigate the impact of post-processed true axial reconstructions of axial head CT scans.
Andrius Estus, BS
Diagnostic and Interventional Radiology Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Image Quality Evaluation In Deep-Learning-Based CT Noise Reduction Using Virtual Imaging Trial Methods: Lesion Characterization
Deep learning-based image reconstruction and noise reduction (DLR) techniques are increasingly adopted in clinical CT to improve image quality at reduced radiation doses. While prior studies have demonstrated benefits for lesion...
Zhongxing Zhou
Diagnostic and Interventional Radiology Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Imaging-Based Evaluation of Gold Nanoparticles In MCF-7 Cells for Nanobrachytherapy Applications.
To synthesize gold nanoparticles Au197 and Au198 and to evaluate their interaction with MCF-7 breast cancer cells using imaging techniques based on Raman spectroscopy and CLSM Confocal Microscopy.
Maria Elisa Chuery Martins Rostelato, PhD
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Imaging Protocol Optimization for MR-Only HDR Brachytherapy Treatment Planning
To optimize a simulation imaging protocol for MR-only treatment planning (MRTP) of high-dose rate (HDR) brachytherapy (BT) in patients diagnosed with prostate cancer.
Matt Goette, PhD
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Impact of Anatomical Changes and PTV Margin Dimensions on Delivered Dose for Prostate SBRT Patients Treated on an MR-Linac
Accurate delivery of MR-guided adaptive radiotherapy (MRgART) for prostate SBRT is influenced by inter- and intra-fraction motion, planning target volume (PTV) margin selection, and verification adaptation. Our study quantified m...
Jeff D. Winter, PhD
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Impact of Beam Energy and Field Configuration on VMAT TBI Plan Quality
To assess how different treatment planning techniques affect dose homogeneity and OAR sparing in VMAT total-body irradiation (TBI) plans.
Matthew Stephen Andriotty, PhD
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Impact of CBCT Reconstruction and DIR Algorithm on Supraglottic Contour Accuracy In Oropharyngeal Cancer
Accurate delineation of anatomy on cone-beam CT (CBCT) is essential for image-guided and adaptive radiotherapy in head and neck cancer, yet image quality and deformable image registration (DIR) performance remain limiting. This s...
Levent Sensoy, PhD
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Impact of Class-Imbalance Handling on Discrimination and Calibration In Multicenter Radiomic Survival Models
Radiomic survival models often have substantial class imbalance, which can distort patient ranking and reduce the reliability of predicted survival probabilities. This study evaluated commonly used imbalance-handling strategies a...
Hajar Moradmand
Diagnostic and Interventional Radiology Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Impact of Combining Advanced Dynamic Collimator Arc Therapy with Flattening Filter-Free Beams on Plan Quality and Delivery Efficiency In Postmastectomy Radiotherapy
RapidArc Dynamic (RAD) in Eclipse, version 18.1 integrates dynamic collimator rotation with static angle modulated ports (STAMPs) into arc to improve plan quality and treatment time. Flattening filter–free (FFF) beams further red...
Fumiya Tsurumaki
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Impact of Dose- and Function-Based Lung Regions on Radiomics-Based Prediction of Radiation Pneumonitis
Radiation pneumonitis (RP) remains a major toxicity in thoracic radiotherapy. While lung radiomics has shown promise for RP prediction, the optimal region for feature extraction remains unclear. This study investigated whether re...
Shinya Ito
Therapy Physics
0 people interested
Poster
Poster Program
Exhibit Hall | Poster Lounge
Jul 19 · 15:15
Impact of Dose Rate Settings on Delivery Accuracy In Dynamic Swing Arc for Prostate SBRT
Dynamic Swing Arc (DSA) irradiation with the OXRAY radiotherapy system integrates simultaneous gantry rotation and ring motion, enabling high-dose-rate delivery for prostate stereotactic body radiotherapy (SBRT). Although the sys...
Naoki Hayashi, PhD
Therapy Physics
0 people interested