The spread-out Bragg peak (SOBP) technique uses ridge filters to broaden the depth-dose profile, producing a dose distribution similar to a single-field-uniform(SFU) approach. In contrast, the single-energy pristine Bragg peak(SEPBP) approach relies on range...
Author profile
Shannon E. O'Reilly, PhD
University of Wisconsin
A Comprehensive Comparative Study of Proton Flash Techniques for Conformal Pencil Beam Scanning Radiotherapy: Pristine Bragg Peak Vs. Spread-out Bragg Peak
Poster Program · Therapy Physics
Aligning Outreach Curriculum with Learner Demand: Survey-Informed Design of Medical Physics Workshops for Students In Africa
Shortages of trained medical physicists persist across Africa. Needs-assessment surveys were utilized to determine trainee interest and medical physics curricular gaps to aid in design of hands-on outreach workshops for the African School of Physics, a severa...
Poster Program · Education (Innovation in Medical Physics: Arthur Boyer Award)
Commissioning the First Upright Proton Therapy System with Matched Beam Quality In a Synchrotron Based Two-Room Facility
We report the first clinical implementation integrating a 6D upright treatment chair and a vertical CT system for image-guided proton therapy on a synchrotron-based fixed-beamline. This design aims to improve patient workflow and reduce the facility footprint...
Poster Program · Therapy Physics