This study aims to develop the first 4pi dynamic proton arc optimization algorithm which searches for efficient arc trajectories in 4pi space, explores the potential dosimetric improvements in multiple disease sites. Then we demonstrate its feasibility throug...
Author profile
Peilin Liu, MD, MS
Corewell Health William Beaumont University Hospital
This study assessed the impact of machine-specific delivery sequence in quantifying interplay effects for lung stereotactic body radiotherapy (SBRT) between two proton therapy modalities, intensity-modulated proton therapy (IMPT) and spot-scanning proton arc...
This study aims to introduce a new SPArc algorithm with a variable tolerance window (SPArc-variable) to further improve plan quality for patients receiving bilateral breast and regional nodal irradiation, by allowing extra energy layers across specific arc tr...